Manual Reset |
|
upon power loss |
|
|
|
Applications Include:
- Garden Power
Products
- Industrial and
Domestic Products
- Power tools
- Vacuum cleaners
- Irons
|
|
|
RCD Specifications:
- In Line style configuration
- Built-in TEST and RESET buttons
- Pulse current sensitive
- Robust construction, double pole
breaking
- Manual reset upon power loss
- Rated 16A, 250 VAC, 50 Hz
(Depending upon Cordage)
- 10 and 30 mA Residual Current
Trip Levels available
(30 mA is standard and is used with
cords listed below)
- Basic Dimensions: 47x54x160 mm
- Trips in no more than 30 mS
- PG11 waterproof connector and a
clamping ring seal bushing
- IP65 protection (rated for
outdoor use; dustproof and low
pressure hosedowns)
- Temperature range -25C to +40C
- Lighted power on indication
- Available in black, white, or
gray colors (black is standard)
- Tested according to DIN VDE 0661
and EN61540 standards
- Design conformance: BS7071
- CE certified and RoHS compliant
|
|
|
STANDARD RCD CORDSETS |
Part Number |
Amps |
Voltage |
Hz |
Plug Configuration |
Cordage |
Connector
Configuration |
Cord Length
(Feet) |
Accessories |
|
R3B2-F22A-0096 |
10 |
250 |
50 |
AS/NZS 3112 |
1.0mm2, H05VV-F |
IEC 60320 C-13 |
8 |
IEC 60320 C-14 Inlet |
R3B2-F72A-0096 |
10 |
250 |
50 |
AS/NZS 3112 |
1.0mm2, H07RN-F |
IEC 60320 C-13 |
8 |
IEC 60320 C-14 Inlet |
R3B2-F22B-0096 |
10 |
250 |
50 |
AS/NZS 3112 |
1.0mm2, H05VV-F |
IEC 60320 C-15 |
8 |
IEC 60320 C-16 Inlet |
R3B2-F72B-0096 |
10 |
250 |
50 |
AS/NZS 3112 |
1.0mm2, H07RN-F |
IEC 60320 C-15 |
8 |
IEC 60320 C-16 Inlet |
R3B2-F22C-0096 |
10 |
250 |
50 |
AS/NZS 3112 |
1.0mm2, H05VV-F |
IEC 60320 C-15A |
8 |
IEC 60320 C-16A Inlet |
R3B2-F72C-0096 |
10 |
250 |
50 |
AS/NZS 3112 |
1.0mm2, H07RN-F |
IEC 60320 C-15A |
8 |
IEC 60320 C-16A Inlet |
R3B2-G23W-0096 |
15 |
250 |
50 |
AS/NZS 3112 |
1.5mm2, H05VV-F |
Flying Leads |
8 |
Strain Relief |
R3B2-G73W-0096 |
15 |
250 |
50 |
AS/NZS 3112 |
1.5mm2, H07RN-F |
Flying Leads |
8 |
Strain Relief |
R3B2-G23D-0096 |
15 |
250 |
50 |
AS/NZS 3112 |
1.5mm2, H05VV-F |
IEC 60320 C-19 |
8 |
IEC 60320 C-20 Inlet |
R3B2-G73D-0096 |
15 |
250 |
50 |
AS/NZS 3112 |
1.5mm2, H07RN-F |
IEC 60320 C-19 |
8 |
IEC 60320 C-20 Inlet |
R3B2-G23G-0096 |
15 |
250 |
50 |
AS/NZS 3112 |
1.5mm2, H05VV-F |
AS/NZS 3112 |
8 |
AS/NZS 3112 Inlet |
R3B2-G73G-0096 |
15 |
250 |
50 |
AS/NZS 3112 |
1.5mm2, H07RN-F |
AS/NZS 3112 |
8 |
AS/NZS 3112 Inlet |
R3B2-G23V-0096 |
15 |
250 |
50 |
AS/NZS 3112 |
1.5mm2, H05VV-F |
IEC 60309 6H |
8 |
IEC 60309 6H Inlet |
R3B2-G73V-0096 |
15 |
250 |
50 |
AS/NZS 3112 |
1.5mm2, H07RN-F |
IEC 60309 6H |
8 |
IEC 60309 6H Inlet |
R3B2-V23G-0096 |
15 |
250 |
50 |
IEC 60309 6H |
1.5mm2, H05VV-F |
AS/NZS 3112 |
8 |
AS/NZS 3112 Inlet |
R3B2-V73G-0096 |
15 |
250 |
50 |
IEC 60309 6H |
1.5mm2, H07RN-F |
AS/NZS 3112 |
8 |
AS/NZS 3112 Inlet |
|
|
AS/NZS 3112 10A Plug |
AS/NZS 3112 15A Plug |
|
IEC 60309 6H Plug |
AS/NZS 3112 Connector |
|
|
IEC 60309 6H Connector |
IEC 60320 C-13 |
IEC 60320 C-15 |
IEC 60320 C-15A |
IEC 60320 C-19 |
|
|
|