Sales@WorldCordSets.com
Tel 860.763.2100
User Attachable RCD
Plug Head Style
Manual Reset
upon power loss
 
Applications Include:
  • Dry applications only
  • Portable power tools
  • Appliances
  • Extension cords
RCD Specifications:
  • Plug head style configuration
  • Australian AS / NZS 3112 Plug Configuration
  • Built-in TEST and RESET buttons
  • Double pole switching
  • Manual reset upon power loss
    (also known as ACTIVE or Non-Latching)
  • Rated 10A / 230-240 VAC 50 Hz / 2400 Watts
  • 30 mA Residual Current Trip Level
  • Basic Dimensions: 39x43x100mm
  • Less than 30 ms trip response time for ground fault and grounded neutral trip
  • IP3X protection (do not expose the RCD to moisture)
  • Lighted power on indication
  • Available in white or orange colors (white is standard)
  • Tested according to AS3190/1997, AS3100/1994
  • Category 952
  • Accepts cordage 0.75 to 1.5 mm2 PVC ordinary duty
  • Approval by Department of Fair Trading
Part Number Amps Voltage Hz Trip Level
(mA)
Temperature Plug
Configuration
Indoor / Outdoor Accepts
Cordage
Color Dept Fair
 Trade
          Low
C
High
C
         
RPH-M-AUS10-30W 10 230 50 30     AS/NZS 3112 Dry Application 0.75-1.5mm2 White Yes
RPH-M-AUS10-30R 10 230 50 30     AS/NZS 3112 Dry Application 0.75-1.5mm2 Orange Yes


Australian 10 amp